- Power injection capability enables imaging
- MiniLoc® SIS + Power Injection Capability = PowerLoc® SIS
- Small design facilitates ease of dressing
- Low Profile
- Light weight
- Site visibility
- Small footprint
- Dual lumen port adaptable
Available sizes: 19, 20, and 22 Gauge x .75", 1" and 1.5"
Features

The PowerLoc® Safety Infusion Set Family is designed with both the clinician and the patient in mind. The product is indicated for the administration of fluids, drugs and blood sampling via a surgically implanted vascular port. The PowerLoc® Safety Infusion Set Family is the ideal device for accessing PowerPort® devices. This power-combo enables contrast agents to be power-injected. As a result, tissues show up more clearly in CECT scans, making it easier to monitor patient condition.
The PowerLoc® Safety Infusion Set's low profile and small footprint and design make it an ideal needle for dressing the access site. The small size of the needle and the downward angle of the tubing coming off of the back of the device help to maintain dressing integrity.
MiniLoc® SIS + Power Injection Capability =


Safety Mechanism
As the needle is removed from the port and enters the base of the needle, an orange safety shield rotates over the needle point and the needle locks into place. A tactile feel, an audible click and visual confirmation verifies the lockout for safe removal, transporting and disposal of the PowerLoc® needle.
Features and Benefits
- Low profile and small footprint enable the site to be easily dressed
- Downward angled tubing to help maintain dressing integrity
- Ergonomic wing design provides controlled access and site visibility

- Audible "click" and visual indication of lockout
- Dual lumen port adaptable to enable simultaneous infusions through dual lumen ports
- Safety feature conforms to current user technique
- Safety feature covers needlepoint to reduce risk of injury and exposure to bloodborne pathogens
Power Injectable
- 19 gauge and 20 gauge needles withstand up to 5 mL/s power injection of contrast media
- 22 gauge needle withstands up to 2 mL/s power injection of contrast media
- Power sticker notifies CT tech of power injection capability and CT parameters
Identifying Power Injection Capabilities

All Bard Needles
- Are non-coring to minimize septum damage
- Offer optional "Y" injection site for secondary access
- Are available in a variety of lengths and gauge sizes
PowerLoc® Needles are available in a wide variety of sizes to meet your clinical needs. See the specifications tab for available sizes, tubing configurations, and box and case quantities.
Please consult product labels, IFU, and package inserts for any indications, contraindications, hazards, warnings, cautions, and instructions for use.
Kits
With Y-Site
Product Code | Description |
---|---|
2671934 | Port Access Kit, 19 Gauge x .75" |
2672034 | Port Access Kit, 20 Gauge x .75" |
2672234 | Port Access Kit, 22 Gauge x .75" |
2671910 | Port Access Kit, 19 Gauge x 1" |
2672010 | Port Access Kit, 20 Gauge x 1" |
2672210 | Port Access Kit, 22 Gauge x 1" |
2671915 | Port Access Kit, 19 Gauge x 1.5" |
2672015 | Port Access Kit, 20 Gauge x 1.5" |
2672215 | Port Access Kit, 22 Gauge x 1.5" |
Without Y-Site
Product Code | Description |
---|---|
2651934 | Port Access Kit, 19 Gauge x .75" |
2652034 | Port Access Kit, 20 Gauge x .75" |
2652234 | Port Access Kit, 22 Gauge x .75" |
2651910 | Port Access Kit, 19 Gauge x 1" |
2652010 | Port Access Kit, 20 Gauge x 1" |
2652210 | Port Access Kit, 22 Gauge x 1" |
2651915 | Port Access Kit, 19 Gauge x 1.5" |
2652015 | Port Access Kit, 20 Gauge x 1.5" |
2652215 | Port Access Kit, 22 Gauge x 1.5" |
Specifications
PowerLoc® Power-Injectable Infusion Set (Codes with Y-Injection Site)
Product Code | Product Name | Maximum Flow Rate | Packing | Minimum Order Quantity |
---|---|---|---|---|
0671934 | PowerLoc® Safety Infusion Set with Y-injection Site, 19 Gauge x .75" | 5 mL/s | 20 per case | 1 case |
0671910 | PowerLoc® Safety Infusion Set with Y-injection Site, 19 Gauge x 1" | 5 mL/s | 20 per case | 1 case |
0671915 | PowerLoc® Safety Infusion Set with Y-injection Site, 19 Gauge x 1.5" | 5 mL/s | 20 per case | 1 case |
0672034 | PowerLoc® Safety Infusion Set with Y-injection Site, 20 Gauge x .75" | 5 mL/s | 20 per case | 1 case |
0672010 | PowerLoc® Safety Infusion Set with Y-injection Site, 20 Gauge x 1" | 5 mL/s | 20 per case | 1 case |
0672015 | PowerLoc® Safety Infusion Set with Y-injection Site, 20 Gauge x 1.5" | 5 mL/s | 20 per case | 1 case |
0672234 | PowerLoc® Safety Infusion Set with Y-injection Site, 22 Gauge x .75" | 2 mL/s | 20 per case | 1 case |
0672210 | PowerLoc® Safety Infusion Set with Y-injection Site, 22 Gauge x 1" | 2 mL/s | 20 per case | 1 case |
0672215 | PowerLoc® Safety Infusion Set with Y-injection Site, 22 Gauge x 1.5" | 2 mL/s | 20 per case | 1 case |
PowerLoc® Power-Injectable Infusion Set (Codes without Y-Injection Site)
Product Code | Product Name | Maximum Flow Rate | Packing | Minimum Order Quantity |
---|---|---|---|---|
0651934 | PowerLoc® Safety Infusion Set without Y-injection Site, 19 Gauge x .75" | 5 mL/s | 20 per case | 1 case |
0651910 | PowerLoc® Safety Infusion Set without Y-injection Site, 19 Gauge x 1" | 5 mL/s | 20 per case | 1 case |
0651915 | PowerLoc® Safety Infusion Set without Y-injection Site, 19 Gauge x 1.5" | 5 mL/s | 20 per case | 1 case |
0652034 | PowerLoc® Safety Infusion Set without Y-injection Site, 20 Gauge x .75" | 5 mL/s | 20 per case | 1 case |
0652010 | PowerLoc® Safety Infusion Set without Y-injection Site, 20 Gauge x 1" | 5 mL/s | 20 per case | 1 case |
0652015 | PowerLoc® Safety Infusion Set without Y-injection Site, 20 Gauge x 1.5" | 5 mL/s | 20 per case | 1 case |
0652234 | PowerLoc® Safety Infusion Set without Y-injection Site, 22 Gauge x .75" | 2 mL/s | 20 per case | 1 case |
0652210 | PowerLoc® Safety Infusion Set without Y-injection Site, 22 Gauge x 1" | 2 mL/s | 20 per case | 1 case |
0652215 | PowerLoc® Safety Infusion Set without Y-injection Site, 22 Gauge x 1.5" | 2 mL/s | 20 per case | 1 case |