S<span>HERLOCK</span> 3CG™ Diamond Tip Confirmation System

The SHERLOCK 3CG™ Diamond Tip Confirmation System (TCS) fully integrates magnetic tracking and ECG-based peripherally inserted central catheter (PICC) tip confirmation technology, which includes P-wave highlighting and max P-wave identification in adult patients with a present, identifiable, and consistent P-wave.

Features

Getting to the Heart of the Matter

Clinicians using SHERLOCK 3CG™ TCS for PICC placement have eliminated harmful radiation from confirmatory chest X-rays and reduced costs to their healthcare facilities.1

S<span class="font12">HERLOCK</span> 3CG&trade; Diamond TCS

1 Data on file. Bard Access Systems, Salt Lake City, UT. Potential cost savings calculated by number of X-rays averted times the cost of the X-ray.

Site~Rite&reg; 8 Ultrasound System

SHERLOCK 3CG™ Diamond TCS provides an enhanced user interface with updated functionality.

P-wave highlighting—Helps the clinician determine if the P-wave is present, identifiable, and consistent.

Max P-wave identification—Enhances the user interface by identifying max P-wave with stylet color and shape change, as well as ECG highlight and color change.

In addition, SHERLOCK 3CG™ Diamond TCS includes all of the great features of SHERLOCK 3CG™ TCS.

Benefits

Indicated for use as an alternative method to chest X-ray and fluoroscopy for PICC tip placement confirmation in adult patients with a present, identifiable, and consistent P-wave

Immediate confirmation of PICC tip position at the bedside and immediate release of the PICC line

Decreases time from initiation of insertion procedure to release for IV therapy as compared to “blind” catheter placements confirmed with chest X-ray2

Eliminates costs associated with confirmatory chest X-ray and time previously spent waiting for X-ray confirmation readings2

Eliminates confirmatory chest X-ray exposure to the patient and you

Not only are we saving the time it takes to get the chest X-ray read, but more importantly, we’re decreasing the amount of radiation exposure to our patients.

—Adventist Health System

Click here to read full testimonial.

Features

SHERLOCK 3CG™ Diamond TCS provides an enhanced user interface with updated functionality.

Simultaneous view of catheter tip tracking and ECG
Integrates catheter tip tracking and ECG confirmation on the same display

Static ECG baselineProvides comparative ECG waveform for interpretation of P-wave changes and to assist in maximum P-wave identification

Dynamic ECG waveformMeasures changes in P-wave morphology to allow you to position the catheter tip in proximity to the cavoatrial junction

Maintain sterile fieldThrough-drape connection allows you to maintain a maximal barrier sterile field during placement. The probe and wireless remote allow you to maintain sterility while interfacing with SHERLOCK 3CG™ TCS

Tip confirmation documentationAllows for PICC tip location to be easily documented in a patient's chart or stored on the SHERLOCK 3CG™ TCS System

Guideline complianceHelps you comply with AVA and INS guidelines for proper PICC placement by helping to position the PICC tip in proximity to the cavoatrial junction

S<span class="font12">HERLOCK</span> 3CG&trade; TCS System

Getting to the heart of the matter

Click to discover the journey of a PICC.

S<span class="font12">HERLOCK</span> 3CG&trade; TCS System website

Clinical Study

Getting to the heart of the matter

Using X-ray to confirm PICC tip placement wastes clinical care time, exposes patients to harmful radiation, and delays medical therapy. The SHERLOCK 3CG™ Tip Confirmation System (TCS) gets to the heart of the matter by using an adult patient's cardiac electrical activity to position the tip of the PICC in close proximity to the cavoatrial junction (CAJ). Final tip location is confirmed by the nurse at the bedside, and infusion therapy can begin immediately without the need for a confirmatory chest x-ray.

Clinical Study Results

In a clinical study, 99.1% of 114 PICCs were placed at the CAJ or within +/- 1 cm using Bard tip confirmation technology.

For full study information, click here.

Data on File (Bard Access Systems, Inc., Salt Lake City, Utah)

Hardware Options

SHERLOCK 3CG™ TCS simplifies the PICC insertion process by combining PICC tip placement technology into select Site~Rite® Ultrasound systems.

The Site~Rite® 8 Ultrasound System is currently available with integrated SHERLOCK 3CG™ Diamond TCS.

The Site~Rite® 8 Ultrasound System with integrated SHERLOCK 3CG™ TCS is a "one-stop-shop" for PICC placements, allowing you these capabilities:

  • Evaluate and assess patient vasculature
  • Select and access the appropriate vessel
  • Use tip tracking technology to locate and navigate the catheter tip to the SVC
  • Use ECG technology to distinguish changes in P-wave amplitude and identify max P-wave
  • Confirm catheter tip placement at the CAJ without the need for a confirmatory chest X-ray
  • DICOM (on select systems) or printed documentation

Standalone

SHERLOCK 3CG™ Diamond TCS is also available as a separate standalone system for customers not using a Site~Rite® Ultrasound System with integrated SHERLOCK 3CG™ Diamond TCS. This device provides the same great tip tracking and ECG technologies of the integrated system but provides flexibility for use across multiple imaging platforms.

Product Codes

Hardware Product Codes

Product Code Hardware
9770130 SHERLOCK 3CG™ TCS Netbook Display
9770131 SHERLOCK 3CG™ TCS Sensor
9770132 SHERLOCK 3CG™ TCS Standalone System
9770133 SHERLOCK 3CG™ TCS for the MER
9770068 SHERLOCK 3CG™ TCS Remote Control
9770116 Medical Equipment Roll Stand (MER)

SHERLOCK 3CG™ Diamond TCS requires the use of SHERLOCK 3CG™ TPS enabled catheters. Compatible PICC kits codes below:

Power PICC Solo 2 & FT

PowerPICC SOLO®2 Catheters with SHERLOCK 3CG™ TPS Stylet

Product Code Catheter Size Lumens Tray
1194108D 4 F Single Max Barrier
1194108 4 F Single Full
1295108D 5 F Dual Max Barrier
1295108 5 F Dual Full
1295108FD 5 F Dual Max Barrier (PowerPICC® FT)
1295108F 5 F Dual Full (PowerPICC® FT)
1395108QD 5 F Triple Max Barrier
1395108Q 5 F Triple Full
S1395108D 5 F Triple Max Barrier (PowerPICC® Provena™)
S1395108 5 F Triple Full (PowerPICC® Provena™)
1396108D 6 F Triple Max Barrier
1396108 6 F Triple Full
PowerPICC & FT

PowerPICC® Catheters with SHERLOCK 3CG™ TPS Stylet

Product Code Catheter Size Lumens Tray
1173108D 3 F Single Max Barrier (PowerPICC® SV)
1173108 3 F Single Full (PowerPICC® SV)
1174108D 4 F Single Max Barrier
1174108 4 F Single Full
1274108D 4 F Dual Max Barrier (PowerPICC® SV)
1274108 4 F Dual Full (PowerPICC® SV)
1175108D 5 F Single Max Barrier
1175108 5 F Single Full
1275108D 5 F Dual Max Barrier
1275108 5 F Dual Full
1275108FD 5 F Dual Max Barrier (PowerPICC® FT)
1275108F 5 F Dual Full (PowerPICC® FT)
1385108QD 5 F Triple Max Barrier
1385108Q 5 F Triple Full
S1385108D 5 F Triple Max Barrier (PowerPICC® Provena™)
S1385108 5 F Triple Full (PowerPICC® Provena™)
1386108D 6 F Triple Max Barrier
1386108 6 F Triple Full