- Choice of enhanced over-the-wire placement kit or Modified Seldinger Technique (MST) kit with maximal
barrier components - Power injectable
- Maximum flow rate of 5 mL/sec
- Reverse taper hub
- Exclusive bifurcation design
Available sizes: 5 Fr. Single-Lumen, 6 Fr. Dual-Lumen and 6 Fr. Triple-Lumen

Features
The PowerHohn* catheter is now available
in both over-the-wire and Modified Seldinger
Technique (MST) kit configurations.
- Bedside CVC placement using MST with maximal barrier components
- Compliance with Joint Commission1, IHI2, and CDC3
initiatives through the use of maximal barrier components - The PowerHohn* catheters allow injection of contrast
media for power injection computed tomography scans
at a maximum of 5 mL/sec and a power injector
alarm setting at a maximum of 300 psi - Small extension leg clamps clearly communicate the maximum
flow rate of 5 mL/sec - PowerHohn* catheters incorporate an exclusive bifurcation
design and are clearly labeled to differentiate them from
non-power injection catheters - PowerHohn* catheters are indicated for Central Venous Pressure Monitoring
- PowerHohn* catheters have depth markings every 1 cm on the catheter body
- The reverse taper hub gently plugs the insertion site
- All PowerHohn* catheters are StatLock® stabilization device compatible
- "Power Injectable" is printed on each extension leg for easy identification after catheter placement
- Marked Nitinol or Standard Guidewire with Gold Tungsten Tip
- Easy-to-Read I.D. Tags Indicate maximum injection rates and prompt users to check catheter patency

Indications For Use
PowerHohn* catheters are indicated for short or long term access to the central venous system. They are designed for administering I.V. fluids, blood products, drugs and parenteral nutrition solutions, as well as blood withdrawal and power injection of contrast media. The maximum recommended infusion rate is 5ml/sec. The maximum pressure of power injectors used with the PowerHohn* catheter may not exceed 300psi.
Warning: Failure to warm contrast media to body temperature or ensure patency of the catheter prior to power injection may result in catheter failure.
Warning: Do not exceed the maximum flow rate of 5ml/sec. Exceeding the maximum flow rate of 5ml/sec may result in catheter failure and/or catheter tip displacement.
Warning: Power injector machine pressure limiting feature may not prevent over pressurization of an occluded catheter.
1, 2, 3 Joint Commission National Patent Safety Goals, (IHI) Institute for Healthcare Improvement, (CDC) Centers for Disease Control.
Please consult product labels, IFU and package inserts for any indications, contraindications, hazards, warnings, cautions and instructions for use.
Specifications
PowerHohn Central Venous Catheters
| Lumens | Catheter Size | Lumen Gauge Size | Average Gravity Flow Rate | Priming Volumes |
|---|---|---|---|---|
| Single | 5 Fr | 18 Ga. | 1693 | 0.6 |
| Dual | 6 Fr | 18 Ga. / 18 Ga. | 1334 / 1334 | 0.60 / 0.60 |
| Triple | 6 Fr | 17 Ga. / 19 Ga. / 19 Ga. | 1146 / 446 / 446 | 0.66 / 0.45 / 0.45 |
Powerhohn Central Venous Catheter Trays
| Product Code | Catheter Type |
|---|---|
| AVA31851 | 5 Fr SL Maximal Barrier Tray |
| AVA32861 | 6 Fr DL Maximal Barrier Tray |
| AVA33861 | 6 Fr TL Maximal Barrier Tray |
| 0601611 | 6 Fr DL Full Tray |
| 0600510 | 5 Fr SL Basic Tray |
| 0600610 | 6 Fr DL Basic Tray |
Kit Components
| Description | Maximal Barrier Standard Tray (MST) |
Full Tray (Over-the-wire) |
Basic Tray (Over-the-wire) |
|---|---|---|---|
| PowerHohn* CVC | • | • | • |
| Measuring tapes | • | ||
| Bouffant cap | • | ||
| Gown | • | ||
| Gloves | • | ||
| Mask(s) | • | • | |
| Chloraprep* One-Step Applicator (tinted) | • | ||
| Chloraprep* One-Step Applicator (non-tinted) | • | • | |
| Wipe, 70% Isopropyl Alcohol | • | ||
| Povidone Iodine Ointment | • | ||
| Drape, absorbent | • | • | |
| Drape, fenestrated | • | ||
| Drape, fenestrated, full-body | • | ||
| Towel, Absorbent | • | ||
| Scissors | • | ||
| Syringe, Sodium Chloride, 10ml | • | ||
| Lidocaine | • | • | |
| Needle, Safety Hypodermic, 25 G | • | ||
| Needle, Hypodermic, 25 G | • | ||
| Needle, Hypodermic, 22 G | • | ||
| Tunneler | • | • | |
| Needle, Safety Introducer, 21 G | • | ||
| Needle, Introducer, 21 G | • | • | |
| Introducer, Safety Peripheral IV Catheter 20 G | • | ||
| Guidewire, Marked, Nitinol, 50 cm | • | ||
| Guidewire, Marked, Stainless Steel, 70 cm | • | • | |
| Needle Holder | • | • | |
| Microintroducer | • | ||
| Dilator | • | • | |
| Safety Scalpel | • | • | • |
| Aspiration device | • | • | |
| Syringe(s) | • | • | • |
| End cap(s) | • | ||
| Injection cap(s), non-latex | • | • | |
| StatLock* Stabilization Device | • | ||
| Biopatch* Protective Disk w/ CHG | • | ||
| Gauze | • | • | |
| Surgical Tape | • | • | |
| Tape Strips | • | ||
| Adhesive dressing | • | • | |
| Suture | • |
Resources
Please refer to the below-listed Instructions for Use (IFUs) for any indications, contraindications, hazards, warnings and cautions.